This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Nexans’ NEWSENSE microcables open up new dimensions in invasive surgery

01 May 2018

Nexans developed a new micro-extrusion process that creates the thinnest possible insulating jacket to enable minimally invasive medical cables to be manufactured with diameters of less than 0.1mm.

Modern medicine is on a constant quest to develop minimally invasive surgical and diagnostic procedures. This presents medical device manufacturers with a major, ongoing challenge to increase the miniaturisation of their components. Providing the vital power and data connection for these miniature devices is driving the development of a new generation of microcables with diameters of just 0.1mm or even less. Nexans’ introduces its range of NEWSENSE microcables with an insulation jacket of only 15 microns thick.

Designing cables smaller than the eye can see

While medical microcables must ensure performance, reliability and safety essential for any medical application, their size also plays decisive role for reducing impact of invasive procedures. One of the main limiting factors in the miniaturisation of cables is the thickness of the insulating jacket. Until now, with “standard” extrusion process, we could not go below 30 microns thickness – or 30 thousandths of a millimetre (mm). Although at this size the insulation is just a little thinner than the finest human hair (75-125 microns) it would still take up some 84 percent of the overall cross-section of a 0.1mm diameter cable. 

With a new extrusion process, Nexans was able to reduce the insulation jacket of its NEWSENSE cables down to 15 microns thickness. This allows the manufacture of smaller diameter cables that offer a variety of advantages for invasive surgery. They are easier to insert inside catheters, such as when used in trans-catheter applications in cardiovascular electrophysiology and neurology. They are also less traumatic for patients when used for direct insertion in the body, such as with pacemakers.

A further benefit of the new design is that it offers the capability to incorporate more cables within the same cross-section to allow increased functionality. The extruded layer is also smooth, regular and cosmetically appealing and easy to strip for termination.

One of the first NEWSENSE designs is a new space-saving cable for trans-catheter applications. This design uses two AWG52 (20 micron copper diameter) insulated wires stranded together as a twisted pair. Shielding against external electromagnetic disturbances is provided by 15 micron diameter wires in silver plated copper alloy. Externally, the cable has a biocompatible, low-friction fluoropolymer jacket extruded with a 0.14mm final outer diameter.

“The medical cable market is growing by some five to 10 percent year on year, and the development of the new microcables will enable Nexans to reinforce its already strong position and open up some exciting possibilities for new applications,” said Thierry Malvache, Nexans Medical Product Manager. “This project has really pushed the envelope of what is possible with extrusion technology, and its success is a tribute to the high level of cooperation between our medical cable factory and the Nexans Research Centre in Lyon.” 

NEWSENSE microcables, together with other medical cables, are manufactured at Nexans France specialised facility in Draveil, France. 


Contact Details and Archive...

Print this page | E-mail this page

Coda Systems