This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Sponsored Article

Some straight talking on torque

06 May 2015

Howard Venning explores the topic of connector coupling or mating torque, which, among other factors, is also likely to have a big impact on connector life expectancy.

Author, Howard Venning

Anyone who has worked in an electronics measurement lab and used coaxial connectors will know the importance of mating torque and will typically have a range of torque spanners complementing their coax connectors, adaptors and test cables. Valid, repeatable test results rely on a constant mating torque.

The correct torque also ensures the longest life of your expensive measurement standard connectors, cables and adaptors, especially considering the repeated connect – disconnect cycles many connectors go through during their life, not to mention the test equipment itself. 

RF and Microwave equipment typically relies upon an RF connector pair when it comes to connecting one part of the system to the other. This might be via a coax cable, a pair of back to back connectors or when you have different connector types via a coaxial adaptor. The system designer, and those responsible for system installation and maintenance, has to consider an increasing array of different connector types.

Over the past few years we have seen an increase in the types of connectors used, plus the range of uses. Industry standards such as the BNC, TNC, N-type and SMA have seen numerous alternatives, each offering some technical advantage.

In wireless applications the N-type was the ‘industry standard’, but we have seen the 7/16 DIN become the preferred connector, especially where low passive intermodulation (PIM) needs to be achieved. However, the 7/16 DIN is now seeing the 4.1-9.5 DIN being proposed due to its smaller size and increased frequency performance whilst maintaining its good PIM performance. In high frequency applications the SMA has been complemented by the 3.5mm, 2.92mm, 2.4mm, 1.85mm and 1.00mm connectors as microwave systems get closer to 110GHz.

A similar situation applies on the production line, where certain tests need a specified coupling torque to be used during the measurement process.  A good example is when using a PIM Tester, as the handbook will always specify a torque setting for the connectors used in the measurement system.  However, the correct mating torque is also just as important in the field as it is in the lab, but for slightly different reasons.

Whilst any wireless system that is designed to ensure a specified PIM performance will need to follow the same guidelines as used in production test, one might think that because the connection is only being made once, it is less important. This is not the case. Under-tighten a connector and you may get a high loss or intermittent contact which might not reveal itself for some time. Worse still is to over tighten a connector pair. To understand why we need to look at the way coax connectors actually meet.

Typically, the male/female centre contacts have a mating plane that is specified in the connector design reference drawing. During connector production and/or assembly the centre contact is positioned with reference to the reference plane to within a set dimension, typically a few tenths of a millimetre. This ensures that when connectors are correctly mated the centre pins mate without damage.

Over tightening coax connectors has the effect of compressing the internal components and, in severe cases, causing pressure on the mating centre pins, which in turn can lead to failure of the joint between the centre pin and whatever it is connected to. In the case of cables, this might be the cable centre conductor, although this is relatively rare given the flexibility of coax cables. This problem can be mitigated by using a connector with a ‘captive centre contact’ design.

In our experience the real problem comes when you are connecting to a system component such as a load, attenuator or coupler. These components typically have a connector centre contact soldered directly to a PCB or internal component such as a resistor. Compression on this joint will probably lead to failure. The solder joint between centre contact and internal component will have the minimum of solder used to ensure as good an RF performance as possible, as ‘over-engineering’ with excessive use of solder might result in poor voltage standing wave ratio. 

Howard Venning is with Aspen Electronics