This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

KEB drive controllers monitor sub-mounted braking resistors

24 July 2023

When it comes to absorbing short-peak currents, braking resistors already mounted on the inverter are a good choice. However, when operating inverters, braking resistors can also become thermally overloaded – with costly consequences. A special feature in the COMBIVERT F6 drive controllers from KEB Automation solves this problem.

The trend in plant and machine design is increasingly moving towards the re-use of regenerative energy in the system. Wherever possible, operation in a DC network is used, whereby the energy is actively utilised in the respective application. 

If the braking energy exceeds the demand of the other axes or if an emergency stop is carried out, braking resistors are always required.

For the COMBIVERT F6 drive controllers (starting from housing size 4), KEB offers sub-mounted braking resistors, which are installed on the rear side of the inverter cooling element. This saves space in the control cabinet and avoids the otherwise necessary wiring effort for the user. 

The braking resistors are cooled directly via the liquid heat sink, which allows them to absorb significantly more power.

Integrated temperature model protects against overheating 
Available as built-in or push-through versions, the liquid-cooled F6 inverters in all device versions have an integrated thermal resistance model that is activated when sub-mounted braking resistors are used and protects them from thermal overload. The monitoring function noticeably increases safety and prevents high costs due to machine failures.   

“In unfavourable circumstances, the braking resistor can be permanently damaged or destroyed. To prevent this from happening in the first place, the temperature monitoring function for KEB’s sub-mounted braking resistors is already preset in the drives,” says Tim Aufderheide, Applications Engineer at KEB Automation.

Predefined limit values
The state space model installed in the F6 drive controllers simulates the temperature of the braking resistor and detects when predefined limit values are reached. If this is the case, the frequency inverter goes into a fault state to prevent possible damage.

Application areas that benefit from the protection function in the COMBIVERT F6 drive controllers include the plastics and recycling industries. “Sub-mounted braking resistors and the matching monitoring function are always useful when selective peak loads need to be absorbed. This is the case, for example, when opening the clamp in injection moulding machines or when dealing with stubborn materials in a shredder,” says Aufderheide. 

For more information, please visit www.keb.co.uk


Contact Details and Archive...

Print this page | E-mail this page