This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Variable speed drive profile is now available for CC-Link

12 May 2010

A variable speed drive profile is now available for CC-Link, the open industrial fieldbus protocol. This will reduce the engineering time, cost and effort required by manufacturers and users to integrate drives into open communications networks. The Anybus-CompactCom drive profile is a range of products for CC-Link. It extends the Anybus-CompactCom concept by increasing and improving the functionality of the software so that compliance with the latest communication standards for drives is ensured.

Device profiles specify how a network communication system can used for devices for a specific application area. The use of profiles reduces engineering costs significantly, since the meaning of parameters related to the application is precisely specified.

All the Anybus-CC drive profile modules throughout the range have the same hardware interchangeability as standard Anybus-CC modules. Their software interface permits a standardised access to the drive parameters independent of the network type.

The drive profile software interface functions are similar to the standard Anybus-CC modules, but offer enhanced features. Automation devices that have an existing standard Anybus-CC slot need only to upgrade the software interface before their first use. After this, they can use the full range of enhanced standard modules and drive profile modules for an even more flexible communication interface.
 
The Anybus-CompactCom drive profile CC-Link communication module provides the inverter drive with instant CC-Link connectivity via the uniform Anybus-CompactCom host interface. Any device that supports this standard can take advantage of the features provided by the module, allowing seamless network integration regardless of network type. The module support drive operations according to the inverter profile of CC-Link. When used in standard mode the module supports CC-Link version 1.1 but during initialisation can be configured for CC-Link version 2.0 functionality.

Key features of the drive profile include:
 
Remote bus device
Galvanically isolated bus electronics
CC-Link parameter channel support according to the Inverter Profile
Up to 128 I/O (bit) points and 16 words (16 bit) of data (CC-Link v1.1)
Up to 896 I/O (bit) points and 128 words (16 bit) of data (CC-Link v2.0)
Automatic CC-Link System Area handshaking
Possibility to customize Vendor Code, Model Code and Version via application interface

Technical spec. 
Size:   52 mm x 50 mm x 22 mm
Power Supply:   3,3 Volt
Temperature:   -40 to +70°C
Baud Rate:   156kbit/s to 10Mbit/s
Configuration Method:   Application interface (switch 1&2)
Application Interface:   Parallel and serial
Order Code:   AB6373 (Without Housing)
 